Water-based intumescent fireproof coating for structural steel. Formulated with acrylic emulsion, ammonium polyphosphate intumescent system, char-forming agents, blowing agents, and additives. On exposure to fire, the coating expands (intumesces) to form a thick, insulating char layer that protects the steel substrate.
Recommended Uses
- Suitable for interior and exterior mineral substrates, concrete, mortar and prepared wall surfaces in general protective and decorative coating service.
Technical Specifications
| Product Family | Waterborne |
| Coating Layer | All |
| Component System | 1K or ready-to-use system, confirm from current TDS |
| Recommended Use Snapshot | Suitable for interior and exterior mineral substrates, concrete, mortar and prepared wall surfaces in general protective and decorative... |
| Surface Dry | <=2h hard dry<=24h |
| Hard Dry | <=24h |
| Dry Film Thickness | 1.0happrox.1.0mm; 2.5happrox.3.5-5.0mm(depending on specific product) |
Confirm current TDS/SDS, packaging, shelf life, and destination-market requirements before quotation or shipment.
Request Current TDS/SDSPerformance Data
| Water Resistance | >=24hno abnormality |
Application Guide
| Surface Preparation | Steel or metal surfaces shall be dry, clean and free from oil, dust, mill scale and loose rust. Use the specified hand-tool, power-tool or blast-cleaning grade according to the coating system and service environment. |
| Application Environment | Apply with application temperature 5-35 deg C; relative humidity <= 85%; substrate temperature at least 3 deg C above the dew point. |
| Application Method | Apply by airless spray, air spray, spray, brush, roller. Recommended dry film thickness: 1.0happrox.1.0mm; 2.5happrox.3.5-5.0mm(depending on specific product). Use compatible thinner/cleaner such as clean water where permitted where specified. Mix, thin and recoat according to site conditions and the coating system requirements. |
Storage & General
| Safety | Confirm substrate condition, compatibility, mixing ratio and application environment before large-area work. Protect from freezing, rain, contamination and direct exposure before the film is fully dry. Store sealed in a cool, dry and ventilated place and dispose of waste according to local regulations. |
Product FAQ
Can I request the current TDS and SDS for Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)?
Yes. Contact the Qilu Paints export team with the product name, destination country, substrate, coating system, and application environment to confirm current TDS/SDS, packaging, and export requirements.
How should Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0) be selected for an export project?
Confirm substrate preparation, exposure environment, target durability, compatible primer/intermediate/topcoat, destination-market documentation, and dangerous-goods classification before quotation or shipment.
What should be checked before applying Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0)?
Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, relative humidity, ventilation, mixing requirements, and recoat interval before application.
How should Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0) be mixed and applied?
Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.
How should unopened Intumescent Fireproof Coating (2.0-2.5/2.0/1.5/1.0) be stored?
Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.
What safety precautions are required during application?
Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.
Manufacturer & Product Data Source
This page is maintained by Shandong Qilu Paints Co., Ltd. for international buyers and is based on Qilu Paints legacy technical product records. Confirm current TDS/SDS, export classification, packaging, shelf life, color, and destination-market requirements with the sales and technical team before quotation, specification, or shipment.
Disclaimer
Interested in This Product?
Contact us for detailed technical data sheets, pricing, and customized solutions for your application.