Alkyd Hammer Finish Paint
1K Top
QL-ALK-X-002 Alkyd

Alkyd Hammer Finish Paint

Description

Formulated with high-performance resin, non-leafing aluminium paste, high-durability pigments, organic solvents, and additives. A single-component decorative topcoat that produces a distinctive, uniform hammer-texture finish without requiring high-temperature baking.

Recommended Uses

  • Designed for decorative and protective finishing of security doors, safes, machine tools, motors, instruments, and metal hardware. Suitable for any metal surface where a premium textured appearance combined with good durability is required.

Best For

  • general steel protection
  • cost-sensitive projects
  • decorative metal work

Buyer Benefits

  • cost-effective protection
  • easy general-purpose application
  • broad color and finish options

Key Features

  • Distinctive, uniform hammer-texture pattern
  • No high-temperature baking required — air-dries at ambient temperature
  • Fast drying: touch dry ≤ 1 hour
  • High hardness after through-cure
  • Bright, full film with excellent color vibrancy
  • Good impact resistance (≥ 40 cm)
  • Good flexibility (1 mm mandrel)
  • Good outdoor durability

Typical Coating System

Typical alkyd system: alkyd anti-rust primer and alkyd enamel topcoat for general atmospheric service.

Technical Specifications

Product Family Alkyd
Coating Layer Top
Component System 1K or ready-to-use system, confirm from current TDS
Recommended Use Snapshot Designed for decorative and protective finishing of security doors, safes, machine tools, motors, instruments, and metal hardware. Suitable...
Typical System Typical alkyd system: alkyd anti-rust primer and alkyd enamel topcoat for general atmospheric service.
Surface Dry ≤1 hr
Hard Dry ≤24 hrs (air dry); ≤3 hrs (bake at 60-70℃)
Dry Film Thickness Not specified
Theoretical Spreading Rate Not specified

Confirm current TDS/SDS, packaging, shelf life, and destination-market requirements before quotation or shipment.

Request Current TDS/SDS

Application Guide

Surface Preparation Substrate must be clean, dry, and free of rust, oil, grease, water, and loose dust. Abrasive Blasting or Power Tool Cleaning to a clean metal surface is recommended. If a primer is used, apply topcoat using the wet-on-wet method. If filler/putty has been applied, sand smooth and remove all dust thoroughly before topcoating.
Application Method Conventional / Airless Spray: Spray pressure: 3–4 kg/cm² Spray distance: 20–25 cm Gun travel speed: slightly slower than standard topcoat application Take a test spray before production to verify texture consistency and uniformity Stir thoroughly before use. If skin has formed, filter before use. After use, seal the container immediately to prevent skinning. Clean spray equipment immediately with thinner after use.

Product FAQ

Can I request the current TDS and SDS for Alkyd Hammer Finish Paint?

Yes. Contact the Qilu Paints export team with the product name, destination country, and application environment to confirm current TDS/SDS, packaging, and export requirements.

How should Alkyd Hammer Finish Paint be selected for a coating system?

Confirm substrate, exposure environment, required durability, compatible primer or topcoat, and destination-market documentation before quotation or shipment.

What should be checked before applying Alkyd Hammer Finish Paint?

Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, and relative humidity before application. Stir thoroughly before use.

How should Alkyd Hammer Finish Paint be stored and handled?

Store sealed containers in a cool, dry, ventilated area away from heat, sparks, and direct sunlight. Follow the current SDS for PPE, ventilation, fire prevention, and waste disposal.

What should be checked before applying Alkyd Hammer Finish Paint?

Confirm substrate cleanliness, surface profile, dew point, ambient temperature, humidity, and compatibility with the primer or topcoat in the coating system.

How should Alkyd Hammer Finish Paint be mixed and applied?

Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.

How should unopened Alkyd Hammer Finish Paint be stored?

Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.

What safety precautions are required during application?

Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.

Product Data Source

This product page is generated from Qilu Paints legacy technical product records. Confirm SDS, TDS, export classification, packaging, and destination-market requirements with the sales and technical team before quotation or shipment.

Interested in This Product?

Contact us for detailed technical data sheets, pricing, and customized solutions for your application.