Normas aplicables

ISO 12944 SY/T 0447-2014 buried steel pipeline epoxy coal tar coating reference
Solicitar cotización del sistema

Application Scenarios

Crude oil storage tanks, refined oil storage tanks, chemical storage tanks, and other liquid storage tank anti-corrosion coating applications.

Selection Logic

Oil tank coating selection should separate external atmospheric exposure from internal chemical or immersion exposure. The tank shell, roof, bottom plate, internal wall, and buried or contact areas may need different coating systems, surface preparation levels, and inspection requirements.

External Anti-Corrosion

CoatProductCoatsDFT (μm)
PrimerEpoxy Zinc-Rich Primer160-80
IntermediateEpoxy MIO Intermediate Coat180-100
TopcoatAcrylic Polyurethane Topcoat / Fluorocarbon Topcoat280-100
Total220-360

Internal Anti-Corrosion

CoatProductCoatsDFT (μm)
PrimerEpoxy Anti-Corrosion Primer160-80
TopcoatEpoxy Anti-Corrosion Topcoat2100-120
Total160-200

Surface Preparation

  • Blast cleaning Sa2½
  • Surface roughness Rz 50-85 μm
  • Cleanliness: Free of oil, dust, and contaminants

Design Life Reference

Design service life: 15-25 years.

  • C3-C4: ordinary outdoor tank farms and general industrial atmospheres.
  • C5: coastal tank farms, high-humidity areas, and aggressive industrial exposure.
  • CX or immersion service: requires project-specific review and current TDS/SDS confirmation.