Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K)
Description
Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2-component) is formulated with high-performance epoxy resin, anti-corrosive pigments, micaceous iron oxide, and imported water-based curing agents. Designed as a water-based intermediate coat for corrosion protection of structural steelwork, bridges, transmission towers, shipping containers, engineering facilities, storage tanks, and similar applications.
Best For
- steel structure protection
- industrial floor systems
- heavy-duty anti-corrosion projects
Buyer Benefits
- strong adhesion to prepared substrates
- good chemical resistance
- suitable for multi-coat protective systems
Key Features
- Flaky micaceous iron oxide creates a maze effect for superior barrier-type rust protection.
- Enhances substrate adhesion and reduces coating shrinkage for improved finish.
- Water-based epoxy micaceous iron intermediate coat minimizes light degradation and boosts weather resistance.
- Compatible with all solvent-based and water-based primers/topcoats.
- Eco-friendly: Water-based formula, zero environmental impact, odorless.
- Safe: Non-flammable, explosion-proof for secure handling and application.
Typical Coating System
Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required.
Technical Specifications
| Product Family | Epoxy |
| Coating Layer | Mid |
| Component System | 2K system, confirm mixing ratio from current TDS |
| Recommended Use Snapshot | steel structure protection, industrial floor systems |
| Typical System | Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required. |
Confirm current TDS/SDS, packaging, shelf life, and destination-market requirements before quotation or shipment.
Request Current TDS/SDSApplication Guide
| Application Method | 1. Application Conditions: Ambient temperature: >10°C Relative humidity: <80% 2. Technical Specifications Coverage: 140-180g/m² Coats: 2 layers Dry film thickness: 40μm per coat Recoat interval: ≥10 hours Induction time: 10-20 minutes Pot life: ≤4 hours (at 23±2°C) 3. Application Guidelines Thinner Options: Distilled water / Deionized water / Tap water Max Thinning Ratio: Air spray: 10-15% Brush/Roller: 0-10% Viscosity: 30-40S (Ford #4 cup, air spray) Spray Nozzle: 1.3-1.5mm Spray Pressure: 0.4-0.6MPa Cleaner: Water 4. System Compatibility Suitable for all solvent-based and waterborne primers/topcoats |
Compatible Products
Product FAQ
Can I request the current TDS and SDS for Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K)?
Yes. Contact the Qilu Paints export team with the product name, destination country, and application environment to confirm current TDS/SDS, packaging, and export requirements.
How should Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K) be selected for a coating system?
Confirm substrate, exposure environment, required durability, compatible primer or topcoat, and destination-market documentation before quotation or shipment.
What should be checked before applying Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K)?
Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, and relative humidity before application. Stir thoroughly before use.
How should Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K) be stored and handled?
Store sealed containers in a cool, dry, ventilated area away from heat, sparks, and direct sunlight. Follow the current SDS for PPE, ventilation, fire prevention, and waste disposal.
What should be checked before applying Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K)?
Confirm substrate cleanliness, surface profile, dew point, ambient temperature, humidity, and compatibility with the primer or topcoat in the coating system.
How should Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K) be mixed and applied?
Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.
How should unopened Water-based Epoxy Micaceous Iron Oxide Intermediate Paint (2K) be stored?
Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.
What safety precautions are required during application?
Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.
Product Data Source
This product page is generated from Qilu Paints legacy technical product records. Confirm SDS, TDS, export classification, packaging, and destination-market requirements with the sales and technical team before quotation or shipment.
Interested in This Product?
Contact us for detailed technical data sheets, pricing, and customized solutions for your application.