Epoxy Floor Intermediate Coat 3078
Description
Epoxy Floor Intermediate Coat 3078 is an epoxy intermediate coat used for industrial floor and concrete substrate projects.
Recommended Uses
- Suitable as an epoxy floor intermediate coat between compatible floor primers and topcoats on properly prepared concrete and cementitious floor substrates.
Best For
- steel structure protection
- industrial floor systems
- heavy-duty anti-corrosion projects
Buyer Benefits
- strong adhesion to prepared substrates
- good chemical resistance
- suitable for multi-coat protective systems
Key Features
- strong adhesion to prepared substrates
- good chemical resistance
- suitable for multi-coat protective systems
Typical Coating System
Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required.
Technical Specifications
| Product Family | Epoxy |
| Coating Layer | Mid |
| Component System | 1K or ready-to-use system, confirm from current TDS |
| Recommended Use Snapshot | Suitable as an epoxy floor intermediate coat between compatible floor primers and topcoats on properly prepared concrete and cementitious... |
| Typical System | Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required. |
| Surface Dry | <=2h hard dry<=24h |
| Hard Dry | <=24h |
| Theoretical Consumption | 0.5-1.0kg/m2 |
Confirm current TDS/SDS, packaging, shelf life, and destination-country requirements before quotation or shipment.
Request Current TDS/SDSApplication
| Surface Preparation | Concrete or cementitious substrates shall be sound, dry, clean, fully cured, and free from laitance, oil, dust, loose material, and curing compounds. Confirm primer adhesion, moisture condition, and recoat interval before applying the intermediate coat. |
| Application Environment | Apply with application under suitable site temperature; relative humidity <= 85% where applicable; substrate temperature at least 3 deg C above the dew point; adequate ventilation. |
| Application Method | Mix the two components thoroughly according to the confirmed ratio and pot life. Apply evenly by roller, squeegee, or suitable floor-coating equipment, keeping coverage and recoat interval consistent with the confirmed floor system. |
Storage and Delivery
| Packaging | 20:520:8 |
| Safety | Confirm substrate condition, compatibility, mixing ratio and application environment before large-area work. Provide good ventilation, keep away from sparks and open flames, and use appropriate personal protective equipment. Do not use material that has exceeded its pot life or has gelled after mixing. Store sealed in a cool, dry and ventilated place and dispose of waste according to local regulations. |
Compatible Products
Epoxy Floor Primer 3001
Epoxy Floor Primer 5007
Solvent-Free Epoxy Floor Primer
Anti Static Epoxy Floor Self Leveling Coating
Epoxy Floor Self Leveling Coating 3066
Epoxy Floor Self Leveling Coating 5036
Epoxy Floor Topcoat 3023
corrosion-c4-high
Related Solutioncorrosion-c5-very-high
Related Solutionindustry-bridge-steel
Related Solutionindustry-oil-tank
Product FAQ
Can I request the current TDS and SDS for Epoxy Floor Intermediate Coat 3078?
Yes. Contact the Qilu Paints export team with the product name, destination country, substrate, coating system, and application environment to confirm current TDS/SDS, packaging, and export requirements.
How should Epoxy Floor Intermediate Coat 3078 be selected for an export project?
Confirm substrate preparation, exposure environment, target durability, compatible primer/intermediate/topcoat, destination-market documentation, and dangerous-goods classification before quotation or shipment.
What should be checked before applying Epoxy Floor Intermediate Coat 3078?
Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, relative humidity, ventilation, mixing requirements, and recoat interval before application.
How should Epoxy Floor Intermediate Coat 3078 be mixed and applied?
Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.
How should unopened Epoxy Floor Intermediate Coat 3078 be stored?
Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.
What safety precautions are required during application?
Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.
Manufacturer & Product Data Source
This page is maintained by Shandong Qilu Paints Co., Ltd. for international buyers and is based on Qilu Paints legacy technical product records. Confirm current TDS/SDS, export classification, packaging, shelf life, color, and destination-market requirements with the sales and technical team before quotation, specification, or shipment.
Disclaimer
Interested in This Product?
Contact us for detailed technical data sheets, pricing, and customized solutions for your application.