Inorganic Zinc-Rich Primer 1506
Description
Inorganic Zinc-Rich Primer 1506 is a inorganic primer designed for industrial and heavy-duty anti-corrosion service.
Recommended Uses
- Suitable as an inorganic zinc-rich primer on abrasive-blasted carbon steel for heavy-duty anti-corrosion systems, steel structures, and industrial equipment where cathodic protection is required.
Best For
- steel structure protection
- industrial floor systems
- heavy-duty anti-corrosion projects
Buyer Benefits
- strong adhesion to prepared substrates
- good chemical resistance
- suitable for multi-coat protective systems
Key Features
- strong adhesion to prepared substrates
- good chemical resistance
- suitable for multi-coat protective systems
Typical Coating System
Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required.
Technical Specifications
| Product Family | Zinc-Rich Primers |
| Coating Layer | Primer |
| Component System | 1K or ready-to-use system, confirm from current TDS |
| Recommended Use Snapshot | Suitable as an inorganic zinc-rich primer on abrasive-blasted carbon steel for heavy-duty anti-corrosion systems, steel structures, and... |
| Typical System | Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required. |
| Color | gray |
| Non-Volatile Content | 75%±3% |
| Dry Film Thickness | 80microns |
| Theoretical Spreading Rate | 0.323kg/m2; surface dry 30min(23±2deg C) |
Confirm current TDS/SDS, packaging, shelf life, and destination-country requirements before quotation or shipment.
Request Current TDS/SDSApplication
| Surface Preparation | Steel surfaces shall be abrasive-blasted to the specified cleanliness and profile for the confirmed coating system. Remove oil, salts, dust, mill scale, rust, and spent abrasive before coating, and apply before flash rusting or contamination occurs. |
| Application Environment | Apply with application under suitable site temperature; substrate temperature at least 3 deg C above the dew point; adequate ventilation. |
| Application Method | Apply mainly by airless spray or conventional spray using equipment suitable for zinc-rich primers. Keep the mixed material agitated to prevent zinc settling, apply the recommended dry film thickness of 80 microns, and follow confirmed mixing, thinning, pot-life, and recoating requirements. |
Storage and Delivery
| Packaging | 4:1 |
| Safety | Confirm substrate condition, compatibility, mixing ratio and application environment before large-area work. Protect from freezing, rain, contamination and direct exposure before the film is fully dry. Do not use material that has exceeded its pot life or has gelled after mixing. Store sealed in a cool, dry and ventilated place and dispose of waste according to local regulations. |
Compatible Products
Aliphatic Polyurethane Topcoat (2-Component)
Fluorocarbon Silver Metallic Topcoat
Fluorocarbon Topcoat 1#
Fluorocarbon Topcoat 2#
corrosion-c4-high
Related Solutioncorrosion-c5-very-high
Related Solutionindustry-bridge-steel
Related Solutionindustry-oil-tank
Product FAQ
Can I request the current TDS and SDS for Inorganic Zinc-Rich Primer 1506?
Yes. Contact the Qilu Paints export team with the product name, destination country, substrate, coating system, and application environment to confirm current TDS/SDS, packaging, and export requirements.
How should Inorganic Zinc-Rich Primer 1506 be selected for an export project?
Confirm substrate preparation, exposure environment, target durability, compatible primer/intermediate/topcoat, destination-market documentation, and dangerous-goods classification before quotation or shipment.
What should be checked before applying Inorganic Zinc-Rich Primer 1506?
Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, relative humidity, ventilation, mixing requirements, and recoat interval before application.
How should Inorganic Zinc-Rich Primer 1506 be mixed and applied?
Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.
How should unopened Inorganic Zinc-Rich Primer 1506 be stored?
Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.
What safety precautions are required during application?
Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.
Manufacturer & Product Data Source
This page is maintained by Shandong Qilu Paints Co., Ltd. for international buyers and is based on Qilu Paints legacy technical product records. Confirm current TDS/SDS, export classification, packaging, shelf life, color, and destination-market requirements with the sales and technical team before quotation, specification, or shipment.
Disclaimer
Interested in This Product?
Contact us for detailed technical data sheets, pricing, and customized solutions for your application.