Overview

Water-based inorganic silicate binder with high zinc loading providing cathodic protection and high-temperature tolerance (to ~400deg C).

Recommended Uses

  • Suitable as a primer on interior and exterior mineral substrates, concrete, mortar and prepared wall surfaces before compatible intermediate coats or topcoats in industrial and heavy-duty anti-corrosion service.

Best For

  • steel structure protection
  • industrial floor systems
  • heavy-duty anti-corrosion projects

Buyer Benefits

  • strong adhesion to prepared substrates
  • good chemical resistance
  • suitable for multi-coat protective systems

Key Features

  • strong adhesion to prepared substrates
  • good chemical resistance
  • suitable for multi-coat protective systems

Typical Coating System

Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required.

Technical Data

Product Family Waterborne
Coating Layer Primer
Component System 1K or ready-to-use system, confirm from current TDS
Recommended Use Snapshot Suitable as a primer on interior and exterior mineral substrates, concrete, mortar and prepared wall surfaces before compatible...
Typical System Typical epoxy system: epoxy primer, optional epoxy intermediate coat, and polyurethane or fluorocarbon topcoat when exterior color and weather resistance are required.
Color gray
Gloss (60°) flat
Non-Volatile Content (%)50±2
Surface Dry <=30min hard dry<=24h
Hard Dry <=24h
Dry Film Thickness (microns)50-75
Theoretical Spreading Rate approx.3.5

Confirm current TDS/SDS, packaging, shelf life, export classification, and destination-market requirements before quotation or shipment.

Request Current TDS/SDS

Performance Data

Heat Resistance 400deg C

Application Guide

Surface Preparation The substrate shall be sound, dry, clean and fully cured. Remove dust, laitance, grease, loose layers, mildew and other contaminants; repair cracks or uneven areas before coating.
Application Environment Apply with application temperature 5-40 deg C; relative humidity <= 65%; substrate temperature at least 3 deg C above the dew point.
Application Method Apply by airless spray, air spray, spray, brush. Recommended dry film thickness: (microns)50-75. Mix, thin and recoat according to site conditions and the coating system requirements.

Export & Storage Notes

Packaging 21:9
Safety Confirm substrate condition, compatibility, mixing ratio and application environment before large-area work. Protect from freezing, rain, contamination and direct exposure before the film is fully dry. Do not use material that has exceeded its pot life or has gelled after mixing. Store sealed in a cool, dry and ventilated place and dispose of waste according to local regulations.

Product FAQ

Can I request the current TDS and SDS for Water-Based Inorganic Zinc-Rich Primer?

Yes. Contact the Qilu Paints export team with the product name, destination country, substrate, coating system, and application environment to confirm current TDS/SDS, packaging, and export requirements.

How should Water-Based Inorganic Zinc-Rich Primer be selected for an export project?

Confirm substrate preparation, exposure environment, target durability, compatible primer/intermediate/topcoat, destination-market documentation, and dangerous-goods classification before quotation or shipment.

What should be checked before applying Water-Based Inorganic Zinc-Rich Primer?

Check surface cleanliness, surface profile, ambient temperature, substrate temperature, dew point, relative humidity, ventilation, mixing requirements, and recoat interval before application.

What should be checked before applying Water-Based Inorganic Zinc-Rich Primer?

Confirm substrate cleanliness, surface profile, dew point, ambient temperature, humidity, and compatibility with the primer or topcoat in the coating system.

How should Water-Based Inorganic Zinc-Rich Primer be mixed and applied?

Stir thoroughly before use. For multi-component products, mix base and curing agent according to the current TDS, observe induction time and pot life, and only thin with the recommended thinner.

How should unopened Water-Based Inorganic Zinc-Rich Primer be stored?

Store in sealed original containers in a cool, dry, ventilated place away from heat, sparks, and direct sunlight. Confirm shelf life and packaging with the current TDS/SDS before shipment.

What safety precautions are required during application?

Use suitable PPE, provide ventilation, keep away from ignition sources, and follow the current SDS for handling, fire protection, first aid, and waste disposal.

Manufacturer & Product Data Source

This page is maintained by Shandong Qilu Paints Co., Ltd. for international buyers and is based on Qilu Paints legacy technical product records. Confirm current TDS/SDS, export classification, packaging, shelf life, color, and destination-market requirements with the sales and technical team before quotation, specification, or shipment.

Manufacturer Shandong Qilu Paints Co., Ltd.
Export contact sales@qilupaints.com
Technical review Current TDS/SDS required

Disclaimer

The listed data are typical reference values. Actual consumption, drying time, recoating interval and final performance depend on substrate condition, film thickness, temperature, humidity, ventilation, application method and coating system. For certification, special exposure, fire rating, potable-water contact, food contact or VOC-limit requirements, use the applicable test report, certificate or confirmed technical agreement.

Interested in This Product?

Contact us for detailed technical data sheets, pricing, and customized solutions for your application.

AI assistant online