ISO 12944 C4 : forte corrosivité
ISO 12944: C4

ISO 12944 C4 : forte corrosivité

Systèmes de revêtement pour sites industriels et côtiers avec humidité accrue et exposition saline.

Normes applicables

ISO 12944-2: C4 ISO 12944-5 coating system selection
Demander un devis système

Environment Definition

ISO 12944 C4 covers high atmospheric corrosivity. It is often relevant for industrial atmospheres, coastal environments with moderate salt exposure, high-humidity process areas, and structures exposed to more aggressive outdoor service.

Typical examples include coastal buildings, chemical plant steelwork, swimming pool building structures, transport infrastructure, and outdoor industrial equipment.

Coating Selection Logic

C4 projects usually need a multi-layer protective system. The system should be selected around surface preparation, zinc-rich or anti-corrosion primer choice, high-build barrier thickness, and a topcoat that can handle UV, weathering, and the target color life.

For severe marine, chemical, splash, or long-life infrastructure projects, review C5 or CX instead of treating C4 as a universal high-end system.

Starting System Pattern

LayerTypical roleNotes
Surface preparationAbrasive blast cleaning is normally expected for new steelConfirm Sa grade, profile, dust, oil, and soluble salt limits.
PrimerEpoxy zinc-rich, inorganic zinc, or suitable epoxy anti-corrosion primerZinc-rich systems need compatible intermediate coats and controlled application.
IntermediateHigh-build epoxy MIO or barrier coatBuilds dry film thickness and slows moisture/oxygen penetration.
TopcoatAliphatic polyurethane, acrylic polyurethane, fluorocarbon, or project-specific topcoatSelect by UV exposure, color retention, gloss, and maintenance interval.

Technical Review Points

  • Confirm whether salt exposure is atmospheric only or includes splash/immersion.
  • Review compatibility between zinc-rich primer and intermediate coat.
  • Define total DFT and per-layer DFT based on expected durability.
  • Confirm current Qilu Paints TDS/SDS, mixing ratio, induction time, pot life, and recoat windows.

Besoin d’une solution anticorrosion personnalisée ?

Notre équipe technique peut concevoir le système de revêtement anticorrosion optimal selon votre environnement spécifique et vos conditions d’utilisation.

Contacter l’équipe technique